Hard seal gate valve

Hard seal gate valve

Size:2”~ 12”

Pressure Rating:PN1.0MPa, PN1.6MPa, 150LB

Material:Ductile Iron

Design Standard: DIN3352,MSS SP-70

Inspection Standard:DIN3230,API598

Application medium:water, oil, gas

Application Temperature:0-120℃

Applied projects:Water conservancy/ fire/hVAC/building water supply and drainage

Appliction:To be used as the regulating and cut off device in the fluid pipeline of following system:Petroleum/Electricity/Metallurgy/Water/Sewage/Energy/Construction

Description

Wesdom gate valve is a gate plate of an opening and closing part. The movement direction of the gate plate is perpendicular to the direction of the fluid.

The gate valve can only be fully opened and fully closed, and cannot be adjusted or throttled. The gate valve is sealed by the contact of the valve seat and the gate plate. Usually, the sealing surface will be welded with metal materials to increase wear resistance, such as 1Cr13, STL6, stainless steel, etc. The gate has a rigid gate and an elastic gate. According to the different gate plates, the gate valve is divided into a rigid gate valve and an elastic gate valve.

Standards:

①Design and Manufacture Conform to AWWA, BS5163, DIN-F4,F5

②Dimensions Conform to EN1092-2,ANSI B16.5

③Face to Face dimensions Conform to EN558-1, API 594, DIN3202

④Testing Conform to EN12266-1, API598

DN L d C x-n T f g
50 178 165 125 4-18 19 2 99
65 190 185 145 4-18 19 2 118
80 203 200 160 4-18 8-18 19 3 132
100 229 220 180 8-18 19 3 156
125 254 250 210 8-18 19 3 184
150 267 285 240 8-23 19 3 211
200 292 340 295 8-23 12-23 21 3 266
250 330 395 350 355 12-23 12-25 22 3 319
300 355 445 400 410 12-23 12-25 25 4 370
350 381 515 460 470 16-23 16-25 25 4 430
400 405 580 515 525 16-26 16-31 28 4 475
450 432 650 565 585 20-26 20-31 29 5 530
500 457 670 715 620 650 20-26 20-34 29 5 580
600 508 780 810 725 770 20-30 20-36 38 5 680

 

Installation and precautions

Do not lift the handwheel during the transportation process, and do not allow collision. If it is stored for a long time, it should be placed in a cool and dry place, and it is not allowed to store or stack in the open air.

Pay attention to the following work when installing the valve:
(1) Wipe off the dirt attached to the valve;
(2) Check whether the operating conditions are consistent with the valve’s pressure resistance, temperature resistance, and corrosion resistance;
(3) Check whether the fasteners of each part of the valve are loose or damaged;
(4) Manually operated valves should be flexible and free from jamming
(5) The pipe flanges on both sides connected to the valve must be parallel and coaxial;
(6) When tightening flange bolts, tighten them symmetrically and alternately;
(7) This valve should be installed on the horizontal pipeline;
(8) If there are no special instructions in the order contract, only vertical installation and use are allowed, and the non-verticality shall not exceed 5°;
(9) When the handwheel rotates clockwise, it is the closing direction, and vice versa, it is the opening direction.
(10) For the new pipeline, the valve should be fully opened before watering;
(11) A certain number of expanders or expansion bends are installed on the pipeline;
(12) Large-caliber valves should have fulcrums.

After the valve is installed, the user can formulate a maintenance cycle according to the opening and closing frequency, and fill the actuator with lubricating grease on time according to the cycle regulations